-The compressor shall operate under the following load:


Release time:

2021-09-15

Pressure, temperature and oil supply of lubricating oil. Oil pressure shall not be less than 1kg/cm 2 before it is fed into the distribution piping. The lubricating oil in the crankcase or fuselage shall be wet: The compressor with a crosshead shall not exceed 60℃. Those without crosshead shall not exceed 70℃.

 

1. Pressure, temperature and oil supply of lubricating oil. Oil pressure shall not be less than 1kg/cm 2 before it is fed into the distribution piping. The lubricating oil in the crankcase or fuselage shall be wet: The compressor with a crosshead shall not exceed 60℃. Those without crosshead shall not exceed 70℃.

2. The compressor runs smoothly, and the sound of all moving parts should be normal.

3. Measure the inlet and outlet water temperature and check the supply of cooling water. The cooling water is not allowed to flow intermittently and there are bubbles and blockage. Cooling water drainage temperature shall not exceed 40℃.

4. All connecting flanges, shaft seals, inlet and exhaust valves, cylinder heads and water jackets shall not leak air, oil or water.


5. The inlet and exhaust valves should work normally and be safe and sensitive.

6. The connecting parts shall not be loose.

7. All levels of exhaust temperature and pressure should be measured in accordance with the provisions of the technical conditions.